Adding devices, step by step.
Add a switch from the template library and a server you describe yourself, with their ports, and place both in a rack. 5 steps, about five minutes.
Before you start
You need a rack to put the devices in. This guide uses Rack A from the rack guide. A device is a name, a type and a set of ports; the template library supplies the ports for common hardware.
A device from the template library
-
Step 1 of 5
Add the switch
For hardware in the library, PatchMap builds the whole port layout for you.
- Open Devices and click Add device.
- Name it CORE-SW-01 and leave Type on switch.
- Set Vendor to Cisco and Model to Catalyst 9300-48P.
- Click Template available — Apply. A summary of the ports appears under the model.
- Under Rack Assignment choose Rack A and U position 40.
- Click the create button, which now reads Create + 53 ports.
You should see: The switch is created with all 53 ports and placed at U40 in Rack A.
The green strip is the matched template; the button shows how many ports it will create. -
Step 2 of 5
Check its ports
Every port is listed with its speed, media and connector, ready to connect.
- Open CORE-SW-01 from the Devices list.
- Scroll to Ports.
You should see: The console port, the management port and the 48 access ports, each showing Free with a Connect button.
Ports created from the template.
A device you describe yourself
-
Step 3 of 5
Add the server
Hardware that is not in the library is added the same way, just without ports.
- Click Add device. Name it APP-SRV-01 and set Type to server.
- Enter its vendor and model. If a template is offered you can apply it; this example assumes none is.
- Set U Height to 2, choose Rack A and U position 20.
- Click Create Device.
You should see: The server is created with no ports and placed at U20 to U21.
-
Step 4 of 5
Add its ports in one go
A range adds a run of numbered ports without typing each one.
- Open APP-SRV-01 and, under Ports, click Bulk Add Ports.
- In Range, type eth0-eth3.
- Leave Speed on 1G and Media on copper, and choose a connector if you record them.
- Click Preview to check the names, then Create 4 Ports.
You should see: The server now has eth0 to eth3.
Preview first, so a typo never creates 48 wrong ports. -
Step 5 of 5
See both in the rack
Devices are drawn at their real U position and height.
- Open Racks and click Rack A.
You should see: CORE-SW-01 at U40 and APP-SRV-01 across U20 and U21.
Drag a device to another U to move it.
Good to know.
Placing by dragging
A device created without a rack appears under Unassigned in the device tray beside the rack. Drag it onto a U slot to place it. If the tray is hidden, click Show device tray first.
Placing from a phone
Dragging is a desktop job. On a phone, open the device, click Edit and set its Rack and U position there.
Renaming a port
Click a port's name in the Ports list, type the new name and press Enter. A cable plugged into the port stays where it is and shows the new name. Two ports on one device cannot share a name.
Model not in the library?
Use Request it in the form and it is added for everyone, or build your own template under Settings, Device templates.
One port at a time
Under Ports, type a name and click Add Port. Speed, media and connector stay as you last set them, so a row of similar ports is quick.
Copying a device
Clone on a device's page makes a copy with the same ports. Rename it and give it a rack.
Swapping for a different model
Replace on a device's page changes its model and ports in one go. You choose which new port each connected cable moves to, and it keeps its name and rack position.
Half-width and 0U kit
Tick Half width for devices that sit two to a U. A PDU can be mounted in the side bay instead of taking a U.
Patch panels
Panels are devices too, with a front and a rear on every port. They have their own guide.
Stop guessing where the cable goes.
Free while in beta · No credit card · UK-hosted · Online in minutes